DINI ARGEO DIGITAL COLUMN LOAD CELL, IN STAINLESS STEEL, “RCD” SERIES

RCD LOAD CELL: INSTALLATION KIT
  • The KRCA kit allows a correct installation of the RCD load cells below the weighbridge plate.
  • The kit consists of an upper cup with anti-rotation system, a lower cup and a two-hole plate for easier and faster fixing. All components are made from nickel-plated steel.
  • Both cups are designed for optimal operation in conjunction with the cell’s self-centring spherical bases, allowing their proper oscillation and return to position.
  • The cups are also fitted with triple function integrated washers:
    - they keep lubricating grease in its place.
    - they simplify the proper positioning and levelling of the cell and support it during installation/maintenance.
    - they protect the system by preventing dirt and water from accumulating on the bottom of the cup, thus maintaining the correct oscillation and mechanical compensation of the load cells over time

Digital version of compression load cells, ideal for CE-M approved weighbridges, tanks, silos, etc. Manufactured in STAINLESS STEEL, with IP68 protection, 4000 divisions, fitted with “rodent proof” armoured cable. 


CAPACITIES (kg): 30000/40000.


OIML R60. C4 precision class.


Load cells with stainless steel body. Degree of protection IP68.


18m Armoured Rodent Resistant Cable, with standard Stainless Steel Armor.


Low Profile Height of only 130mm.


TECHNICAL FEATURES

  • METROLOGICAL:
  • Rated capacity (Cn): 30/40t
  • Combined error: ± 0,014 %Cn
  • Temperature effect on zero: 0,0016 %Cn/°C
  • Temperature effect on sensitivity: 0,0012 %Cn/°C
  • Creep error (30 min.): 0,021 %Cn

    LEGAL METROLOGY OIML R60

  • Accuracy class: C4
  • Max. number of intervals (nmax): 4000e OIML
  • Minimum verification interval (vmin): 10000
  • Z= Emax/(2xDR): 4000

    ELECTRICAL

  • Nominal range of excitation voltage: 10 - 16Vdc
  • Rated output: 200000d
  • Current consumption: 35mA
  • Conversion type: Delta-sigma
  • Internal resolution: 24 bit
  • Converter rate: max. 100 conv./sec.
  • RS485 interface communication rate: 4800/19200 bit/sec.
  • Over voltage protection: 10kA/20kV (8/20µs) - IEC61000-4/5

    GENERAL

  • Service temperature range: -20 ~ +60 °C
  • Compensated temperature range: -10 ~ +40 °C
  • Safe load limit: 150% Emax
  • Ultimate overload: 300% Emax
  • Protection degree IP68
  • Load cells with stainless steel body
  • 6-core armoured cable, PVC sheath, 18m length.
  • Nickel plated steel cable gland.
  • Armoured Anti Rodent Cable with Stainless Steel Armour.
  • Self-centring spherical bases.
  • Equipped with anti-rotation system, to be combined with KRCA cups for proper operation.